Standard EC1x Chambers

temperature-chamber

The CE approved EC1x models are our most customizable temperature test chambers. They are available in sizes ranging from 0.37 ft3 to 6.16 ft3 of working volume. The EC1X uses vertical air flow with convection style heating and has a temperature range of -184°C to 315°C (using LN2) and -73°C to 315°C (using LCO2). The EC1X uses the advanced and extremely flexible TC10 controller to provide features such as non-volatile memory to store user temperature profiles and parameters, an additonal probe (for monitoring and control of product temperature), adjustable ramp rate, power down restart, etc. Built in IEEE-488 (GPIB), RS232/RS422 remote interfaces allow uploading & downloading of user temperature profiles and data logging.

The EC1x supports several safety features including a mechanically or electronically adjustable over temperature limit protection module, upper and lower software temperature limits, processor watchdog timer as well as open and short probe detection.

The EC1x model temperature chambers can be customized to suit your testing needs. Optional features such as circular ports, adjustable shelves and window doors can be installed to facilitate test set up and fixtures inside the work space. An N2 gas purge is available to provide a nitrogen atmosphere during high temperature testing. Coolant features such as 2 or 3 tank auto switching valves, LN2 auto line purge and redundant valves are available to accomodate user's cooling requirements. See our EC1x Chamber Summary Table to compare models.

EC1A Specs (.37 ft3)(pdf)

Voltage Options: 120/240 VAC (50/60Hz)
Power: 1600 Watts
Rate: 30C/min
Air Flow: 60CFM
Workspace Dims: 10"(W) x 8"(H) x 8"(D)
Overall Dims: 17.5"(W) x 13.25"(H) x 20"(D)
Volume: .37 ft3
Weight: 38 lbs
Controller: TC10

Standard Options Available
  • 19" Rack Ears (installed)
  • 120/240 VAC
  • 1",2" or 3" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC1A-PM Specs (.37 ft3) (pdf)

Voltage Options: 120/240 VAC (50/60Hz)
Power: 1600 Watts
Rate: 30C/min
Air Flow: 60CFM
Workspace Dims: 10"(W) x 8"(H) x 8"(D)
Overall Dims: 17.5"(W) x 13.25"(H) x 20"(D)
Volume: .37 ft3
Weight: 38 lbs
Controller: TC10

Standard Options Available
  • 120/240 VAC
  • 6"(W) x 5"(H) x 1/4"(T) window (installed)
  • (2) 1" circular ports (installed)
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC11A Specs (.37 ft3)(pdf)

Voltage Options: 240 VAC only (50/60Hz)
Power: 4200 Watts
Rate: 60C/min
Air Flow: 120CFM
Workspace Dims: 10"(W) x 8"(H) x 8"(D)
Overall Dims: 17.5"(W) x 13.25"(H) x 20"(D)
Volume: .37 ft3
Weight: 38 lbs
Controller: TC10

Standard Options Available
  • 19" Rack Ears (installed)
  • 240 VAC only
  • 1",2" or 3" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC11A-PM Specs (.37 ft3) (pdf)

Voltage Options: 240 VAC only (50/60Hz)
Power: 4200 Watts
Rate: 60C/min
Air Flow: 120CFM
Workspace Dims: 10"(W) x 8"(H) x 8"(D)
Overall Dims: 17.5"(W) x 13.25"(H) x 20"(D)
Volume: .37 ft3
Weight: 38 lbs
Controller: TC10

Standard Options Available
  • 240 VAC only
  • 6"(W) x 5"(H) x 1/4"(T) window (installed)
  • (2) 1" circular ports (installed)
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC10 Specs (.7 ft3)(pdf)

Voltage Options: 120/240 VAC (50/60Hz)
Power: 1600 Watts
Rate: 30C/min
Air Flow: 60CFM
Workspace Dims: 12"(W) x 9.75"(H) x 10.25"(D)
Overall Dims: 21"(W) x 16"(H) x 24"(D)
Volume: .7 ft3
Weight: 49 lbs
Controller: TC10

Standard Options Available
  • 120/240 VAC
  • 1",2",3" or 4" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC11 Specs (.7 ft3)(pdf)

Voltage Options: 240 VAC only (50/60Hz)
Power: 4200 Watts
Rate: 48C/min
Air Flow: 120CFM
Workspace Dims: 12"(W) x 9.75"(H) x 10.25"(D)
Overall Dims: 21"(W) x 16"(H) x 24"(D)
Volume: .7 ft3
Weight: 50 lbs
Controller: TC10

Standard Options Available
  • 240 VAC only
  • 1",2",3" or 4" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC12 Specs (2.2 ft3)(pdf)

Voltage Options: 120/240 VAC (50/60Hz)
Power: 2200 Watts
Rate: 15C/min
Air Flow: 150CFM
Workspace Dims: 20"(W) x 12"(H) x 16"(D)
Overall Dims: 30"(W) x 19.5"(H) x 30"(D)
Volume: 2.2 ft3
Weight: 80 lbs
Controller: TC10

Standard Options Available
  • 120/240 VAC
  • 1",2",3" or 4" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC13 Specs (3 ft3)(pdf)

Voltage Options: 240 VAC only (50/60Hz)
Power: 3000 Watts
Rate: 15C/min
Air Flow: 300CFM
Workspace Dims: 20"(W) x 12"(H) x 22"(D)
Overall Dims: 30"(W) x 19.5"(H) x 36"(D)
Volume: 3 ft3
Weight: 98 lbs
Controller: TC10

Standard Options Available
  • 240 VAC only
  • 1",2",3" or 4" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC15 Specs (5 ft3)(pdf)

Voltage Options: 240 VAC only (50/60Hz)
Power: 6000 Watts
Rate: 24C/min
Air Flow: 600CFM
Workspace Dims: 20"(W) x 12"(H) x 36"(D)
Overall Dims: 30"(W) x 19.5"(H) x 43.5"(D)
Volume: 5 ft3
Weight: 138 lbs
Controller: TC10

Standard Options Available
  • 240 VAC only
  • 1",2",3" or 4" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)

EC16 Specs (6.16 ft3)(pdf)

Voltage Options: 240 VAC only (50/60Hz)
Power: 6000 Watts
Rate: 24C/min
Air Flow: 600CFM
Workspace Dims: 22"(W) x 22"(H) x 22"(D)
Overall Dims: 32"(W) x 29.5"(H) x 36"(D)
Volume: 6 ft3
Weight: 139 lbs
Controller: TC10

Standard Options Available
  • 240 VAC only
  • 1",2",3" or 4" circular ports
  • Hinged Door with or w/o Window
  • Pull Off Door with or w/o Window
  • Shelf w/pilaster clips
  • LN2 or LCO2 cooling
  • Door Sensor
  • Gas Purge with or w/o Needle Valve
Valve Options
  • Line Purge (LN2)
  • 2 tank (LN2)
  • Redundant (LN2)
  • 2/3 tank (LCO2)